376E/CC726E Intrinsically Safe accelerometer and charge amplifier system
High temperature vibration sensor

Product Specs PDF Category Comparison Table

Features

High temperature charge mode accelerometer
Industrial ruggedness
Charge output
Ground isolated
500°C (260°C) operation for the accelerometer
158°C (70°C) operation for the power supply

Accessories supplied

SF6 mounting stud (International customers specify mounting requirements)
Calibration data (level 3)


  Model Sensitivity
+/-Tolerance
Low freq High freq Max temp Exit Hazardous
area ?
376E/CC726E 100 mV/g
+/-10%
1 Hz
60 CPM
15.0 kHz
900.0 kCPM
500 °F
260 °C
Side exit   Hazardous area  

An orange star(Popular) indicates models most commonly used by industry.


Get Acrobat ReaderAcrobat® Reader® software is required to read PDF files.
Get Acrobat Reader here...

376E/CC726E hazardous area classifications:
FM - CL I II III T4, DIV 1 GP ABCDEFG, DIV 2 GP ABCDFG

 

Wilcoxon: The industry leader for over 40 years!
Wilcoxon Research, Inc. 20511 Seneca Meadows Parkway Germantown, MD 20876
1-800-WILCOXON (1-800-945-2696)    T: 301-330-8811    F: 301-330-8873
E: wilcoxon@meggitt.com.
Meggitt: smart engineering for extreme environments